Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 15(1): 2828, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565532

RESUMO

Tears have emerged as a promising alternative to blood for diagnosing diabetes. Despite increasing attempts to measure tear glucose using smart contact lenses, the controversy surrounding the correlation between tear glucose and blood glucose still limits the clinical usage of tears. Herein, we present an in-depth investigation of the correlation between tear glucose and blood glucose using a wireless and soft smart contact lens for continuous monitoring of tear glucose. This smart contact lens is capable of quantitatively monitoring the tear glucose levels in basal tears excluding the effect of reflex tears which might weaken the relationship with blood glucose. Furthermore, this smart contact lens can provide an unprecedented level of continuous tear glucose data acquisition at sub-minute intervals. These advantages allow the precise estimation of lag time, enabling the establishment of the concept called 'personalized lag time'. This demonstration considers individual differences and is successfully applied to both non-diabetic and diabetic humans, as well as in animal models, resulting in a high correlation.


Assuntos
Lentes de Contato Hidrofílicas , Diabetes Mellitus , Animais , Humanos , Glucose/análise , Glicemia , Lágrimas/química , Diabetes Mellitus/diagnóstico
2.
Sci Adv ; 10(14): eadn3784, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38569040

RESUMO

Conventional power-integrated wireless neural recording devices suffer from bulky, rigid batteries in head-mounted configurations, hindering the precise interpretation of the subject's natural behaviors. These power sources also pose risks of material leakage and overheating. We present the direct printing of a power-integrated wireless neural recording system that seamlessly conforms to the cranium. A quasi-solid-state Zn-ion microbattery was 3D-printed as a built-in power source geometrically synchronized to the shape of a mouse skull. Soft deep-brain neural probes, interconnections, and auxiliary electronics were also printed using liquid metals on the cranium with high resolutions. In vivo studies using mice demonstrated the reliability and biocompatibility of this wireless neural recording system, enabling the monitoring of neural activities across extensive brain regions without notable heat generation. This all-printed neural interface system revolutionizes brain research, providing bio-conformable, customizable configurations for improved data quality and naturalistic experimentation.


Assuntos
Encéfalo , Cabeça , Animais , Camundongos , Reprodutibilidade dos Testes , Crânio , Eletrônica , Tecnologia sem Fio
3.
Nat Commun ; 15(1): 1772, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413568

RESUMO

Current soft neural probes are still operated by bulky, rigid electronics mounted to a body, which deteriorate the integrity of the device to biological systems and restrict the free behavior of a subject. We report a soft, conformable neural interface system that can monitor the single-unit activities of neurons with long-term stability. The system implements soft neural probes in the brain, and their subsidiary electronics which are directly printed on the cranial surface. The high-resolution printing of liquid metals forms soft neural probes with a cellular-scale diameter and adaptable lengths. Also, the printing of liquid metal-based circuits and interconnections along the curvature of the cranium enables the conformal integration of electronics to the body, and the cranial circuit delivers neural signals to a smartphone wirelessly. In the in-vivo studies using mice, the system demonstrates long-term recording (33 weeks) of neural activities in arbitrary brain regions. In T-maze behavioral tests, the system shows the behavior-induced activation of neurons in multiple brain regions.


Assuntos
Eletrônica , Neurônios , Animais , Camundongos , Neurônios/fisiologia , Encéfalo/fisiologia , Crânio/diagnóstico por imagem , Metais , Impressão Tridimensional
4.
Nat Nanotechnol ; 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38225357

RESUMO

Electronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 µm) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium-indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm-2) to elicit neural responses in the retina. Their low Young's modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.

5.
Chem Rev ; 123(19): 11488-11558, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37748126

RESUMO

The eye contains a complex network of physiological information and biomarkers for monitoring disease and managing health, and ocular devices can be used to effectively perform point-of-care diagnosis and disease management. This comprehensive review describes the target biomarkers and various diseases, including ophthalmic diseases, metabolic diseases, and neurological diseases, based on the physiological and anatomical background of the eye. This review also includes the recent technologies utilized in eye-wearable medical devices and the latest trends in wearable ophthalmic devices, specifically smart contact lenses for the purpose of disease management. After introducing other ocular devices such as the retinal prosthesis, we further discuss the current challenges and potential possibilities of smart contact lenses.

6.
ACS Appl Mater Interfaces ; 15(24): 28954-28963, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37283562

RESUMO

For electrocardiogram (ECG) detection, the position of conventional patch-type electrodes based on solid-state metals are difficult to manipulate after attachment and also can lead to poor interface with stretchable, rough skin surfaces. Herein, we present a liquid form of ECG electrodes that can be magnetically reconfigured on human skin by providing its conformal interfacing. These electrodes consist of biocompatible liquid-metal droplets where magnetic particles are homogeneously dispersed, and their conformal contact with skin can yield significantly low impedance as well as high signal-to-noise ratio of ECG peaks. These electrodes are also capable of complex motions such as linear movements, splitting, and merging under external magnetic fields. Furthermore, magnetic manipulation of each electrode position on human skin enables precise monitoring of ECG signals with the change in ECG vectors. The integration of liquid-state electrodes with electronic circuitry demonstrates wireless and continuous ECG monitoring while magnetically moving this entire system on human skin.


Assuntos
Eletrocardiografia , Coração , Humanos , Eletrodos , Monitorização Fisiológica , Metais , Impedância Elétrica
7.
Nano Lett ; 22(19): 7892-7901, 2022 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-36135332

RESUMO

Herein, we present an unconventional method for multimodal characterization of three-dimensional cardiac organoids. This method can monitor and control the mechanophysiological parameters of organoids within a single device. In this method, local pressure distributions of human-induced pluripotent stem-cell-derived cardiac organoids are visualized spatiotemporally by an active-matrix array of pressure-sensitive transistors. This array is integrated with three-dimensional electrodes formed by the high-resolution printing of liquid metal. These liquid-metal electrodes are inserted inside an organoid to form the intraorganoid interface for simultaneous electrophysiological recording and stimulation. The low mechanical modulus and low impedance of the liquid-metal electrodes are compatible with organoids' soft biological tissue, which enables stable electric pacing at low thresholds. In contrast to conventional electrophysiological methods, this measurement of a cardiac organoid's beating pressures enabled simultaneous treatment of electrical therapeutics using a single device without any interference between the pressure signals and electrical pulses from pacing electrodes, even in wet organoid conditions.


Assuntos
Células-Tronco Pluripotentes Induzidas , Organoides , Eletrodos , Coração , Humanos , Metais
8.
Adv Healthc Mater ; 10(17): e2002280, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33724723

RESUMO

Wearable healthcare devices have garnered substantial interest for the realization of personal health management by monitoring the physiological parameters of individuals. Attaining the integrity between the devices and the biological interfaces is one of the greatest challenges to achieving high-quality body information in dynamic conditions. Liquid metals, which exist in the liquid phase at room temperatures, are advanced intensively as conductors for deformable devices because of their excellent stretchability and self-healing ability. The unique surface chemistry of liquid metals allows the development of various sensors and devices in wearable form. Also, the biocompatibility of liquid metals, which is verified through numerous biomedical applications, holds immense potential in uses on the surface and inside of a living body. Here, the recent progress of liquid metal-based wearable electronic devices for healthcare with respect to the featured properties and the processing technologies is discussed. Representative examples of applications such as biosensors, neural interfaces, and a soft interconnection for devices are reviewed. The current challenges and prospects for further development are also discussed, and the future directions of advances in the latest research are explored.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Atenção à Saúde , Eletrônica , Humanos , Metais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...